๐Ÿชœ Stair Calculator

Calculate rise, run, and number of steps for code-compliant stairs. Ensure your stairs meet building code requirements.


Quick Formulaโ€‹

Total Riseโ€‹

Total Rise = Upper Floor Height - Lower Floor Height

Number of Stepsโ€‹

Number of Steps = Total Rise รท Desired Rise per Step

Individual Riseโ€‹

Rise per Step = Total Rise รท Number of Steps

Run (Tread Depth)โ€‹

Run = Number of Steps ร— Tread Depth

Building Code Requirementsโ€‹

International Building Code (IBC)โ€‹

RequirementMinimumMaximumNotes
Rise4"7"Height of each step
Run11"โ€”Tread depth
Headroom6'8"โ€”Clear height above
Width36"โ€”Minimum width
Handrail height34"38"Above tread nosing

Common Calculationsโ€‹

Example 1: Standard Residentialโ€‹

Given:

  • Floor to floor height: 9 feet (108 inches)
  • Desired rise: 7 inches

Calculation:

  • Total rise: 108 inches
  • Number of steps: 108 รท 7 = 15.43 โ†’ 16 steps
  • Actual rise: 108 รท 16 = 6.75 inches per step
  • Run (11" treads): 16 ร— 11 = 176 inches (14'8")

Example 2: Commercial Stairsโ€‹

Given:

  • Floor to floor height: 10 feet (120 inches)
  • Desired rise: 7 inches

Calculation:

  • Total rise: 120 inches
  • Number of steps: 120 รท 7 = 17.14 โ†’ 17 steps
  • Actual rise: 120 รท 17 = 7.06 inches per step
  • Run (11" treads): 17 ร— 11 = 187 inches (15'7")

Rise & Run Relationshipโ€‹

The 2R + T Formulaโ€‹

For comfortable stairs:

2 ร— Rise + Run = 24-25 inches

Example:

  • Rise: 7 inches
  • 2R = 14 inches
  • Run = 25 - 14 = 11 inches

Stair Typesโ€‹

Straight Runโ€‹

  • Simplest - Single straight flight
  • Space efficient - Minimal footprint
  • Best for: Residential, small spaces

L-Shaped (90ยฐ)โ€‹

  • Landing - 90-degree turn with landing
  • More space - Requires more floor area
  • Best for: Medium spaces, better flow

U-Shaped (180ยฐ)โ€‹

  • Two flights - 180-degree turn
  • Most space - Requires significant area
  • Best for: Large spaces, grand entrances

Landing Requirementsโ€‹

When Requiredโ€‹

  • Top and bottom - Always required
  • Every 12 feet - Maximum rise between landings
  • At turns - Required for L/U-shaped stairs

Landing Sizeโ€‹

  • Minimum width - Same as stair width
  • Minimum depth - 36 inches (same as width)

Handrail Requirementsโ€‹

Heightโ€‹

  • 34-38 inches - Above tread nosing
  • Consistent - Same height throughout

Continuityโ€‹

  • Continuous - Uninterrupted along flight
  • Returns - Return to wall at ends
  • Extensions - Extend 12" beyond top/bottom riser

Common Mistakesโ€‹

MistakeProblemSolution
Rise too highUncomfortable, code violationKeep under 7"
Run too shortDangerous, code violationMinimum 11"
Inconsistent riseTripping hazardAll rises must be equal
No landingCode violationAdd landing every 12' rise
Wrong handrail heightCode violation34-38" above nosing

Quick Referenceโ€‹

Standard Dimensionsโ€‹

ApplicationRiseRunNotes
Residential7"11"Standard
Commercial7"11"Standard
Outdoor6-7"12-14"Can be deeper
Basement7-8"9-10"Space constrained


Code Compliance

Stairs that don't meet code can result in failed inspections, rework, and safety hazards. Always check local building codes.